NP-500V型微粒计数系统
|
|
最适宜用于水质纯化的激光液体粒度计数和高灵敏度的浊度计,其适合于卫生和劳动福利部临时政策。非常有用的连续控制滤池的工具(采用在线式型号)。
|
 |
This is also highly sensitive
laser particle counter (turbidimeter) for clean
water, most suitable as the counter measurement
against the provisional guide line for clean water
by Ministry of Health, Labor and Welfare. It is used
as an on-line system, and has a strong effect on the
maintenance and management for a filter basin.
Turbidimeter used exclusively for low
turbidity measurement based on the particle counting
method. |
应用领域:
|
|
产品特点:
|
 |
同时进行微粒计数和浊度测量,其适合于卫生和劳动福利部临时政策 |
 |
照亮测量区域,无微粒漏检 |
 |
在相同直径范围内,能区分霉菌(Chyptosporidium)和鞭毛虫卵(giardia),数据可以快速得到评估 |
 |
具有气泡去除槽,除去空气气泡,以防止测定错误 |
 |
光源采用长寿命的半导体激光器 |
 |
具有RS-232C和4-20mA(4道)的标准信号输出 |
|
Both particle counts and turbidity can be measured simultaneously. |
|
Cryptsporidium and giardia are sorted to be the same particle size, so variation in particle size can be judged easily at a glance. |
|
Deforming bath is equipped with this model for the protection from measuring error caused by air bubble. |
|
A long life semi-conductor laser is used as a light source. |
|
Data analysis and filing software will be available in option. |
|
Contamination detector is equipped with this model. |
|
 |
NP-500V型微粒计数系统技术参数
|
|
测量项目 |
|
测量范围 |
微粒计数:7位数字
浊度:0.0001 ~ 2.0mg/I (可切换到NTU) |
测量时间 |
微粒数据计算时间可以自由设定,从6秒~99分59秒(也可以无间隔设定) |
测量流量 |
50ml/min |
测量粒径 |
6通道:0.5µm,1µm,3µm,7µm,12µm,15µm和更大 |
外形尺寸 |
主机:宽度250mm x 深度335mm x 高度300mm
支架:宽度400mm x 深度400mm x 高度1250mm |
重量 |
约30公斤 |
电源 |
AC电源 |
功率 |
100VA,50/60Hz |
光源 |
半导体激光 |
输出 |
RS-232C,4-20mAx4道,报警联系输出 |
注:此型号的准确度来自于日本颜色研究所(JCRI)的国家标准
|
Dimensions
|
Main
unit
: W
230mm
x D
330mm
x H
290mm
Stand
: W
400mm
x D
400mm
x H
1,205mm
|
Weight
|
Approx.
30kg
|
Power
supply
|
100V
AC,
50 /
60Hz
|
Power
consumption
|
100VA
|
Light
source
|
Semi-conductor
laser
|
Measuring
items
|
Particle
counts
,
turbidity
|
Measuring
range
|
•
Particle
counts
: 0
to
106
/
50ml
•
Turbidity
:
0.0000º
to
2.0º
(NTU
unit)
|
Measuring
method
|
Lateral
scattering
method
|
Flow
volume
for
measurement
|
50
ml /
min.
|
Measuring
time
|
Elapsed
time
for
particle
data
integration
6
sec.
to 9
min.
59
sec.
to
be
arbitarily
set
(possible
without
interval)
|
Measuring
particle
size
|
6
channels
for
0.5µm
to
1µm,
1µm
to
3µm,
3µm
to
7µm,
7µm
to
12µm,
12µm
to
15µm,
15µm
or
more
|
Interface
|
•
RS-232C
: 1
channel
•
Centronics
: 1
channel
•
DC
4-20mA
: 4
channels
(3
channels
for
particle
data,
1
channel
for
turbidity
data,
Resolution
is
selective)
|
|
|
Alarm
|
Upper
limits
of
particle
counts
and
turbidity
are
arbitrarily
selective,
with
a
buzzer
sound
and
3
channels
of
relay
contact
output
when
alarm
is
made.
•
Relay
contact
output
:
Particle
counts,
turbidity
and
equipment
error
•
Relay
contact
output
time:
To
be
retained
unit
next
measurement
result
•
Relay
contact
capacity
:
Load
resistance
at
125V
AC,
0.5A
or
30V
DC,
2A
|
*Turbidity
is
to
be
calibrated
using
polystylene
standard
liquid
prior
to
shipment
from
our
factory.
|
|
|
|
|